High density, double-conversion on-line power protection with scalable runtime
Includes: CD with software, Comms cable, Country-specific detachable power cord, Documentation CD, Installation guide, Network Management Card, Rack Mounting brackets, Rack mounting hardware, Rack Mounting support rails, Temperature Probe, USB cable, Warranty card

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

ECO Mode

Read full description

    Specifications for SRT1000RMXLI-NC

    Battery

    Battery life (max)

    5 year(s)

    Battery recharge time

    1 Hour

    Battery technology

    Sealed Lead Acid (VRLA)

    Battery voltage

    48 V

    Hot-swap battery

    Yes

    Design

    Cable length

    1.5 m

    Certification

    CE, EAC

    Display

    LCD

    Display type

    LCD

    Form factor

    Rackmount

    International Protection (IP) code

    IP20

    LED indicators

    Status

    Product colour

    Black

    Features

    Audible alarm(s)

    Yes

    Crest factor

    3:1

    Emergency Power Off (EPO)

    Yes

    Input frequency

    40/70 Hz

    Input operation voltage (max)

    150 V

    Input operation voltage (min)

    50 V

    Output frequency

    50/60 Hz

    Output operation voltage (max)

    240 V

    Output operation voltage (min)

    220 V

    Output power

    1000 Watt

    Output power capacity

    1 kVA

    Surge energy rating

    432 J

    UPS topology

    Double-conversion (Online)

    Waveform

    Sine

    Logistics data

    Harmonized System (HS) code

    85078000

    Products per pallet

    12 pc(s)

    Operational conditions

    Operating relative humidity (H-H)

    0 - 95 %

    Operating temperature (T-T)

    0 - 40 °C

    Storage relative humidity (H-H)

    0 - 95 %

    Storage temperature (T-T)

    -20 - 50 °C

    Package dimensions

    Depth (package,cm)

    74.9 cm

    Gross Weight (Package, kg)

    29.6 kg

    Height (package,cm)

    24.6 cm

    Width (package,cm)

    59.4 cm

    Ports & interfaces

    Serial interface

    Yes

    Serial interface type

    RJ-45

    SmartSlot

    Yes

    USB 2.0 ports quantity

    1

    USB port

    Yes

    Product dimensions

    Net Weight (Product, kg)

    21 kg

    Product Depth

    50.5 cm

    Product Height

    8.5 cm

    Product Width

    43.2 cm

    Technical details

    Harmonized System (HS) code

    85078000

    Sustainability certificates

    Green Premium, RoHS

    Vendor information

    Brand Name

    Description

    432 Joules, 1 kW, 1 kVA, 2U, 230V, 50/6 0Hz, 3:1, Sine

    High density, double-conversion on-line power protection with scalable runtime
    Includes: CD with software, Comms cable, Country-specific detachable power cord, Documentation CD, Installation guide, Network Management Card, Rack Mounting brackets, Rack mounting hardware, Rack Mounting support rails, Temperature Probe, USB cable, Warranty card

    Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance

    ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

    LCD graphics display
    Text and mimic diagrams that display modes of operation, system parameters and alarms.

    Rack/Tower convertible
    Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

    Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.

    Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.

    Scalable runtime
    Allows additional run time to be quickly added as needed.

    Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

    Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.

    Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.

    LED status indicators
    Quickly understand unit and power status with visual indicators.

    Serial connectivity
    Provides management of the UPS via a serial port.

    InfraStruXure Manager Compatible
    Enables centralized management via the APC InfraStruXure Manager.

    SmartSlot
    Customize UPS capabilities with management cards.

    Network manageable
    Provides remote power management of the UPS over the network.

    Flash upgradeable firmware
    Install maintenance releases of firmware remotely using FTP.

    Plug-and-Play external batteries
    Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

    Rack/Tower convertible
    Protects the initial investment in the UPS when migrati

    User-replaceable batteries
    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean
    Time to Repair (MTTR)

    Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.

    Predictive failure notification.
    Provides early-warning fault analysis ensuring proactive component replacement.

    Disconnected battery notification
    Warns when a battery is not available to provide backup power.

    Audible alarms
    Provides notification of changing utility power and UPS power conditions

    Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.

    Cold-start capable
    Provides temporary battery power when the utility power is out.

    Frequency and voltage regulation
    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

    Power conditioning
    Protects connected loads from surges, spikes, lightning, and other power disturbances.

    Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

    Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.

    Resettable circuit breaker
    Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)